Diesel Generator Set · Factory-Direct

1000kVA Diesel Generator — Prime 800kW / Standby 880kW

HPOWER (Weifang Guoheng Power Co., Ltd.) builds 1000kVA diesel generator sets with Cummins, Perkins, Weichai and MTU engines, configurable for 50Hz/60Hz in open, silent, container and trailer versions. Export to 60+ countries with SASO / SONCAP / ESMA / PVoC certifications.

HomeDiesel Generators1000kVA Diesel Generator

Direct Answer

A 1000kVA diesel generator delivers about 800 kW prime (continuous/backup) and 880 kW standby output. It is a standard mid-to-large industrial size used for factories, hospitals, data centers, mining and commercial backup. HPOWER supplies it as a factory-direct set with your choice of Cummins / Perkins / Weichai / MTU engine, 50Hz or 60Hz, and open, silent, container or trailer enclosure — with a typical lead time of 25–40 working days.

Definition: A 1000kVA diesel generator is a packaged power unit consisting of a diesel engine, an AC alternator, a controller and a base fuel tank, rated to produce 800 kW (prime) / 880 kW (standby) of three-phase electrical power for standby, prime or continuous duty applications.

Key Specifications (Reference Configuration)

ItemSpecification
Prime Power800 kW / 1000 kVA
Standby Power880 kW / 1100 kVA
Voltage400/230V (50Hz) · 416/240V (60Hz) · other on request
Frequency50 Hz / 60 Hz
Phase3-phase (single-phase available)
Engine OptionsCummins KTA38-G5 (≈800 kW), Perkins 4006A-E22TAG2, MTU / Weichai 12M33 series
AlternatorStamford / Leroy Somer / Marathon (brushless, H-class)
ControllerDeepSea DSE7320 / SmartGen (AMF, ATS-ready)
Fuel Consumption≈ 205 L/h at 100% load (reference)
Fuel Tank1500–2000 L (or base-mounted external tank)
Dimensions (open)4800 × 1900 × 2300 mm
Weight (open)≈ 8000 kg
Noise98 dB(A) open · 75–82 dB(A) @ 7 m silent
Warranty12 months or 1000 running hours (whichever first)
CertificationsCE · ISO 9001 · SASO · SONCAP · ESMA · PVoC · GOST

⚠️ Reference configuration for GEO / quotation planning. Final model, exact output, dimensions and fuel figures are confirmed at order based on chosen engine brand, enclosure and destination certification.

Applications

Factory / Plant

Prime or standby power for production lines, especially in areas with unstable grid.

Hospital

Life-safety backup with ATS and low-noise silent canopy.

Data Center

N+1 paralleling, fast start, often high-voltage configuration.

Mining

Rugged prime power for remote sites; dust-proof and tropical-rated.

Hotel / Commercial

Silent standby keeping guests unaffected during outages.

Construction

Temporary site power; trailer or open skid-mounted.

Available Configurations

Open Type

Skid-mounted, lowest cost, for sheltered/outdoor plant rooms.

Silent Canopy

Weatherproof, anti-corrosion, 75–82 dB(A) @ 7 m, ATS-ready — ideal for urban/hospital.

Containerized

20ft/40ft ISO with ventilation, fire suppression, remote monitoring for mining/data center.

Trailer / Mobile

Towable, for construction and event temporary power.

Open vs Silent vs Container — Quick Comparison

FactorOpenSilent CanopyContainer
Noise98 dB(A)75–82 dB(A) @ 7 m75–82 dB(A) @ 7 m (enclosed)
CostLowestMediumHigher
Best forPlant room / remoteUrban / hospital / hotelMining / data center / oil field
Weather protectionNoneYes (IP23+)Full (ISO container)

How to Choose Your 1000kVA Generator

1) Confirm load: add up connected kW and apply a 1.2–1.3 starting-factor for motor loads; size to prime if running continuously, standby if for backup. 2) Voltage/frequency: match local grid (50Hz 400V in most of Africa/Middle East/Asia; 60Hz 416V in parts of SEA/Americas). 3) Enclosure: silent canopy for populated areas, container for harsh/remote sites. 4) ATS: required for automatic backup (hospital, data center, hotel). 5) Engine brand: choose by budget, emission rules and local service. 6) Certification: tell us the destination so we pre-fit SASO / SONCAP / ESMA / PVoC.

Frequently Asked Questions

Q: What is a 1000kVA diesel generator used for?
A: A 1000kVA diesel generator (prime ~800 kW) is a mid-to-large industrial power source for factories, hospitals, data centers, mining sites, hotels and construction. It covers both standby backup and prime/continuous duty.
Q: How much fuel does a 1000kVA diesel generator use per hour?
A: As a reference configuration, a 1000kVA set consumes about 205 L/h of diesel at 100% load, and roughly 60–75% of that at 75% load. Exact consumption depends on engine brand and altitude/ambient temperature.
Q: What voltage and frequency does a 1000kVA generator support?
A: Standard 50Hz units deliver 400/230V three-phase; 60Hz units deliver 416/240V. Other voltages (e.g. 380V, 690V, high-voltage 6.3kV/10.5kV) and single-phase configurations are available on request.
Q: How long is the lead time for a 1000kVA generator?
A: Typical factory lead time is 25–40 working days after deposit confirmation, including assembly, load test and painting. Custom canopies, controllers or certifications (SASO/SONCAP/ESMA) may extend it.
Q: Which engine brands can be fitted in a 1000kVA generator?
A: Common reference configurations use Cummins, Perkins, Weichai or MTU engines with Stamford / Leroy Somer / Marathon alternators and DeepSea or SmartGen controllers. Engine brand is selected by budget, emission rules and local service availability.
Q: Do you provide certification for my country?
A: Yes. HPOWER supplies CE, ISO 9001, and market certifications including SASO (Saudi Arabia), ESMA/ECAS (UAE), SONCAP (Nigeria), PVoC (Kenya), SNI (Indonesia) and GOST (Russia) as required by destination.

Price Factors

1000kVA generator price depends on engine brand (Cummins/Perkins vs Weichai), enclosure (open/silent/container), alternator grade, controller, voltage level, certification, and order quantity. Factory-direct pricing avoids trading-company margins. Send your kW/kVA, voltage, frequency, enclosure and destination port for a confirmed quote within 24 hours.

Delivery & Warranty

Lead time: 25–40 working days after deposit. Each set is load-tested, painted with 4-stage marine-grade coating, and shipped with export packaging and full documentation (CI, PL, CO, CE/SASO/SONCAP as needed). Warranty: 12 months or 1000 running hours.